TF-12/630-25

在线订购

106.jpg
真空灭弧室技术参数说明 Technical Specification of Vacuum Interrupter

序号

No.

主要技术参数

 Main Technical Specification

Type型号

TF-12/630-25

电压参数 Voltage Ratings at Rated Contact Stroke 

1

额定频率Rated frequency (fr

Hz

50

2

额定电压 Rated Voltage (ur)  

kV

12

3

额定短时(1 min)工频耐受电压(ud) 

Rated short-time(1 min) power-frequency withstand ovltage

kV

42

28(空气中in air)

4

额定雷电冲击耐受电压(峰值) (up) Rated Lightning impulse withstand voltage (Peak) 

kV

75

60(空气中in air)

电流参数 Current Ratings

1

额定电流Rated cureent (Ir) 

A

630

2

额定触头压力下限时的回路电阻 Circuit resistance at lowest rated contact force 

30

3

额定短时耐受电流(Ik

Rated short-time withstand current

kA

25

4

额定短路持续时间(tk)Rated duration of short-circuit  

s

4

5

额定峰值耐受电流(Ip) Rated peak withstand current

kA

63

6

额定短路关合电流(IMC)  Rated short-circuit making current

kA

63

7

额定有功负载开断电流(I1Rated active load breaking current

A

630

8

额定闭环开断电流(I2aRated closed-loop breaking current

A

630

9

额定空载变压器开断电流(I3Rated capacity of no-load transformer

A

额定容量1250kVA配电变压器的空载电流No-load current of transformation with rated capacity 

of 1250kVA

★10

额定短路单个电容器组开断电流 Rated breaking current of single capacitor bank (ISb

A

400/630

★11

额定背对背电容器组开断电流Rated breaking current of back-tp-back capacitor bank (Ibb

A

400

机械参数 Mechnical Data

1

运动部分质量 Weight of movable parts

kg

0.4

2

触头自闭力 Closing force due to bellow and atmosphere

N

110±40

3

额定开距下的触头反力 Force required to hold contacts open at full stroke   

N

180±50

对开关机械特性需求 Mechanical Requirements

1

触头开距 Clearance between open contacts

mm

6±1

2

平均分闸速度(触头闭合位置 75%开距) Average opening speed (contact close position~75% contact gap)

m/s

1.2±0.2

3

平均合闸速度(30%开距~触头闭合位置) Average closing speed (30% contact gap-contact close position)

m/s

0.6±0.2

4

额定触头压力 Rated added external contact final force

N

900±100

触头初压力Added external contact force at contact touch point

N

630±45

5

触头合闸弹跳时间 Contact bouncing duration at closing operation

ms

≤2

6

触头合闸和分闸不同期 Closing and opening non-simultaneity of three-phase contacts

ms

≤2

7

分闸触头反弹幅值 Maximum rebound during opening

mm

≤2

寿命Life

1

储存期 Storage life

years

20

2

机械寿命Rated menchanical endurance

Times

10000

3

触头允许磨损厚度 Contacts limit erosion

mm

3           

说 明  Notes

1、★为需要时提供的额定参数。★Rated characteristics to be given on request.

2、额定绝缘测试需要外绝缘保护,比如SF6气体、油或固体绝缘材料等。

      Rated insulation values require external insulation, such as SF6, oil or solid dielectric material etc.

Copyrght 2010-2016 上海兴熔电气有限公司 All Rights Reserved         沪ICP备16034744号
 联系电话:0577-62791593/62739261 传真:0577-62801593 手 机:13868703117 13506554136
本站专业提供:高压负荷开关真空断路器接地开关高压熔管等系列高压电器产品以及最新的行业知识和各类讯息,感谢您的访问与关注!